home  /  insights  /  bga-voiding-head-in-pillow-x-ray
Electrical, Electronics & Batteries

Hidden joints: BGA voiding, head-in-pillow and what X-ray shows

Area-array packages hide every joint under the component. The defects that matter there are invisible to inspection and often pass electrical test at room temperature.

July 30, 2026 · 7 min read

The short answer

Two-dimensional X-ray shows ball presence, gross voiding, bridging and misregistration under a BGA, but because it is a projection it struggles to say where in a joint’s height a feature sits, and head-in-pillow frequently looks normal on it. Area-array packages moved every solder joint underneath the component, where no visual inspection can reach — a deliberate trade for density and electrical performance — so the joints most likely to matter in a failure analysis are the ones nobody has ever looked at. Several of the characteristic BGA defects also pass electrical test at room temperature and only open under thermal or mechanical load. Computed tomography resolves the height information that two-dimensional X-ray struggles to provide. Cross-sectioning remains the reference method for intermetallic structure, crack path and true void geometry, but it is destructive and only examines the joints the section happens to pass through, which is why imaging comes first and selects the cut. Some voiding is normal; what matters is its size, position and consistency.

What this article establishes

  • BGA solder joints sit underneath the package, where no visual inspection can reach, and several characteristic BGA defects pass electrical test at room temperature and only open under thermal or mechanical load.
  • Head-in-pillow, in which the ball and the paste deposit each wet their own side but never coalesce, is dominated by package warpage during reflow, which is a function of package construction, board design and the thermal profile together rather than any single party’s choice.
  • Some BGA voiding is normal; what matters is void size, position and consistency, and a population of boards with abnormal voiding usually points at a process rather than at one bad assembly.
  • Two-dimensional X-ray frequently shows head-in-pillow as normal; computed tomography resolves where in the joint’s height a feature sits, without cutting, and cross-sectioning, the reference method for intermetallic structure, crack path and true void geometry, is destructive and only examines the joints the section happens to pass through, so imaging comes first and selects the cut.
  • Whether a BGA site was reworked is an early question, usually answerable from joint microstructure and assembly records together, and a finding that the site was reworked reallocates responsibility, often away from original manufacture.
  • A failed BGA assembly should be kept intact, unpowered and not reworked, because reflowing a suspect BGA to see whether the fault clears is the single most effective way to lose the answer.

What is head-in-pillow in a BGA solder joint, and what causes it?

Head-in-pillow is a BGA solder joint defect in which the solder ball and the paste deposit each melt and wet their own side but never coalesce into one joint, exactly as the name describes. Under X-ray the ball of a head-in-pillow joint looks present and roughly the right shape. Electrically a head-in-pillow joint may conduct through incidental contact, so the board passes test and ships.

The causes of head-in-pillow are well characterized: package warpage during reflow separating the ball from the paste at the critical moment, oxidation preventing wetting, insufficient paste volume, or a reflow profile that mistimed the two. Warpage is the dominant cause of head-in-pillow, and BGA package warpage is a function of package construction, board design and the thermal profile together rather than any single party’s choice.

What causes voiding in BGA solder joints, and when does voiding matter?

Voiding in a BGA solder joint is gas porosity trapped as flux volatiles escape during solidification, and whether it matters depends on the voids’ size, position and consistency, because some voiding is normal and acceptable. For that reason the guidance in the IPC documents for BGA assembly sets criteria for voiding rather than demanding none.

A void at the package or board interface of a BGA joint, where stress concentrates, is more consequential than one in the bulk of the joint. Large voids reduce a BGA joint’s effective cross-section, raising local current density and thermal resistance.

A population of boards with abnormal BGA voiding usually points at a process — paste, profile, stencil design or via-in-pad without adequate fill — rather than at one bad assembly.

What can X-ray, CT scanning and cross-sectioning each show in a BGA solder joint?

In a BGA solder joint, two-dimensional X-ray shows ball presence, gross voiding, bridging and misregistration; computed tomography resolves where in the joint’s height a feature sits and can identify separation planes and interface voiding without cutting; and cross-sectioning remains the reference method for intermetallic structure, crack path and true void geometry. Two-dimensional X-ray is fast, but it is a projection, so it struggles to say where in a joint’s height a feature sits, and head-in-pillow frequently looks normal on two-dimensional X-ray.

Cross-sectioning, however, is destructive and only examines the joints the section happens to pass through. That is why X-ray and computed tomography imaging come first and select where the cross-section is cut.

What is dye and pry testing on a BGA, and what are its limits?

Dye and pry is dye penetration followed by forced separation, and it is a cheap and genuinely useful technique for BGA solder joints: the dye wicks into any pre-existing crack, and after separation the stained area maps the crack that existed before the test.

The limitation of dye and pry is that it destroys the BGA joint and cannot distinguish a crack it created from one it found unless the staining is unambiguous. Performed before any other examination, dye and pry forecloses cross-sectioning. Performed on a sample after imaging has established what to expect, dye and pry corroborates well.

Why does it matter whether a failed BGA was reworked?

It matters whether a BGA was reworked because a reworked BGA is a different object from an as-built one. Rework subjects the package and the board to additional thermal cycles, frequently with less profile control than production reflow, and it may introduce a different alloy or flux chemistry. Pad damage from removal, residual intermetallic from the original joint, and mixed alloys are all common in reworked BGAs and all detectable.

Establishing whether a BGA site was reworked is therefore an early question in a failure analysis, and it is usually answerable from the joint microstructure and from assembly records together. A finding that a BGA was reworked also reallocates responsibility, often away from original manufacture.

How do circuit board design choices contribute to BGA solder joint failures?

Circuit board design choices contribute to BGA solder joint failures by changing where stress concentrates and where cracks initiate, by promoting voiding, and by driving warpage and thermal gradients. Pad geometry, and whether the pad is solder-mask-defined or non-solder-mask-defined, changes where stress concentrates and where cracks initiate in a BGA joint. Via-in-pad without proper fill and cap provides an escape path that promotes voiding. Board thickness and local copper distribution drive warpage and thermal gradients. These board-side design choices influence the outcome of a BGA assembly as much as the assembly process does.

These board design choices are recoverable from the design files, and comparing them against the BGA package manufacturer’s recommendations is straightforward. A deviation from the package manufacturer’s recommendations is a finding that sits with the board designer rather than the assembler.

Is imaging a cracked BGA joint enough to show that the crack caused the failure?

Not by itself: imaging shows a crack in a BGA joint, but it does not show whether that crack explains the reported symptom, and bridging the two usually needs the joint exercised. Resistance measurement across the suspect net while the assembly is heated, cooled or flexed can reproduce an intermittent open and tie it to a specific location.

Boundary-scan and in-circuit techniques can localize an open to a net without any physical access, which is valuable on BGA packages where probing is impossible. Doing this electrical testing before destructive work means the cross-section is aimed at a BGA joint already known to misbehave, rather than at the one that happened to look worst on the X-ray.

How should a failed BGA assembly be preserved for failure analysis?

A failed BGA assembly should be preserved with the board intact, unpowered and not reworked. Any attempt to repair the failure destroys the evidence of it, and the instinct to reflow a suspect BGA to see whether the fault clears is the single most effective way to lose the answer.

Where the BGA assembly was in a system, the mechanical context is worth keeping too — mounting, standoffs, heatsink clamping and anything imposing load on the board, since those forces act directly on the joints under the package.

This article is general technical orientation on BGA solder joints, not a failure analysis, an engineering opinion, or advice on any specific matter. Determining the cause of a particular incident requires hands-on examination by a credentialed expert.

For informational purposes only. Not engineering or legal advice, and not an opinion on the cause of any specific failure or on the conduct of any party.

Related

The practice area

failure-analysis assistanttriage · not a substitute for an expert
Happy to. Tell me what failed, how it failed, and whether the failed part and the scene are still preserved. That last one often decides what can still be established.